get_customer_info
Retrieve a customer record. Details for contact information and location information.
get_organization_summary
Organization profile, list of all customers, and a site count. This is only available
to organization administrators.
list_customers
Paged list of customers under your organization — ID, name, abbreviation, industry —
with totals (countOnly) and per-customer site counts on request.
This is only available to organization administrators.
list_sites
Paged list of sites visible to your access level. Customer access sees its own sites;
organization administrators narrow by customer, and an un-narrowed call on a large
organization returns a per-customer rollup to pick from.
get_site_info
Detailed information about a specific site. Organization administrators can look up
any site in the organization; customers can only see their own sites.
query_devices
Query across every device you have access to — HVAC units, meters, cold storage
sensors, lighting, refrigeration, generators. Filter by site, category, status,
network, make/model, location, or the Nexus Device they are connected to.
get_device_schedule_history
Schedule history for one device — every time a schedule was set, with full schedule
details (name, type, days, store hours, date range). Identify by your deviceId or the
Nexus Device they are connected to. Most recent first; default limit 50.
get_device_live_settings
Live, current settings from any of your devices. Inspects and returns the current
state of all configurable settings for a device — HVAC, lighting, refrigeration,
generators. Identify by your deviceId or the Nexus Device they are connected to.
Meters are read-only and will return an empty settings object.
search_equipment
Scan your fleet for equipment and asset nameplate information — make, model, serial,
part number, refrigerant, tonnage, voltage. Searches both the recorded asset fields
and the extracted equipment nameplate, so a model search matches either. Use the broad
scan term to find any unit whose nameplate mentions a value anywhere.
Returns a compact asset card per device; nameplate data is captured from the physical
label, so a confidence level is included.
get_device_equipment_info
The full asset and equipment nameplate for one device — make, model, serial, part
number, specifications, refrigerant, and certifications. Identify by your deviceId or
the Nexus Device it is connected to. Includes the confidence and any extraction notes,
since nameplate data is captured from the physical label.
hvac_temperature_analysis
Current status, real-time monitoring, temperature trends, supply/return differentials,
and setpoint deviation for every HVAC unit.
hvac_runtime_analysis
Runtime hours by stage, efficiency scoring, cycling pattern analysis, and runtime
trends — detects short-cycling and uneven load sharing.
hvac_efficiency_analysis
Efficiency metrics, energy consumption estimates, and cost calculations with
configurable utility rates.
hvac_environment_analysis
Indoor air quality scoring, humidity and CO2 monitoring, thermal comfort metrics, and
PPD / PMV-style comfort analysis.
hvac_equipment_analysis
Damper control analysis, economizer performance, and ASHRAE compliance checking — find
units running outside spec.
hvac_predictive_analysis
Maintenance alerts, failure prediction, anomaly detection, and health scoring —
surface issues before they cause downtime.
hvac_portfolio_analysis
Multi-site comparison, benchmarking, and executive summary dashboards across your
portfolio. Customer scope or higher.
hvac_monitoring
Occupancy patterns, schedule optimization, degree-day analytics, hourly dashboards,
data quality, and connectivity health.
power_meter_consumption
Real-time power monitoring, consumption trends with configurable binning, and current
load readings across all meters.
power_meter_quality
Voltage quality analysis, power factor scoring, THD, and phase imbalance detection.
Supports single-phase, 3-phase wye, and delta with wild-leg.
power_meter_demand
Peak demand analysis, demand patterns, interval-based demand calculations,
forecasting, and site-level aggregation with device breakdowns.
power_meter_efficiency
Energy breakdown by phase, cost analysis with configurable rates, and efficiency
metrics for every meter in scope.
power_meter_health
Anomaly detection, predictive maintenance, connectivity checks, and data-quality
auditing to keep meter data trustworthy.
power_meter_reporting
Hourly dashboards, executive summaries, and raw-telemetry dumps — ready-to-share
reports for stakeholders.
cold_storage_monitoring
Raw telemetry, analytics, FDA alerts, danger-zone detection (41–135°F), and location
summaries for freezers and coolers.
cold_storage_overview
Compliance summaries, health metrics, violation rollups, cross-site comparison,
trends, and a full dashboard combining all views in one call.
sensor_analysis
Working-level sensor telemetry — raw rows, per-bin stats, last-reading lookups,
value-based filtering, out-of-range detection, and sensor discovery.
Eleven analysis types over temperature, humidity, CO2, pressure, and more.
sensor_overview
Executive sensor dashboards — system health, critical alerts, real-time
operational metrics, trends, geographic and device-type rollups, and a
flexible multi-field groupBy aggregation.
comfort_score
ASHRAE-based occupant comfort score (0–100) per zone, fusing HVAC unit telemetry with
environment sensors — rating, assessment, a plain-language finding and per-metric
components, or the same score trended over time.
area_climate
Descriptive temperature, humidity and CO₂ statistics per zone (count, min, max,
average, median, spread) with enthalpy, dew point and wet-bulb derivations — the
comfort pipeline's raw numbers, current or trended.
get_alarms
Query active alarms with flexible filters — customer, site, device, severity,
category, alarm code, source, or state. Supports countOnly for dashboards.
alarm_operations
Acknowledge, clear, escalate, suppress, assign, or comment on an alarm. An optional
comment can attach to any command.
change_device_setting
Push setting changes to a connected device (HVAC, lighting, generator). Apply new
settings for one device or at bulk, based on your criteria.
start_equipment_test
Start an automated HVAC/RTU equipment test on one device. Stages come from the
configured test template; rejected if a test is already running. Technician category.
abort_equipment_test
Abort a running test by testId, or the latest active test on a device. Only tests
that are In Progress or Pending can be aborted. Technician category.
get_equipment_test
Read equipment test status and results by testId, device (IMEI / deviceId), or site.
Results are automatically scoped to your license key.
query_equipment_tests
List tests for your customer/sites with filters — status, failed-only, repair-flagged,
cleanup-incomplete, date range, make/model — to browse and pick the test you want.
Filtering on cleanup-incomplete surfaces units whose settings may not have been
restored after testing.
count_equipment_tests_by
Aggregate tests with a GROUP BY count — per status, per site, by result, by make —
for quick fleet roll-ups.
report_equipment_test
Log a manual test result or issue for one device — notes, issue description, and an
optional repair flag. Creates a Reported test record.
generate_report
Turn Markdown or HTML content into a NexRev-branded report, saved and returned as a
time-limited download link (light and dark themes).
generate_data_report
Server-built reports from your data by type — equipment test, FDA cold-storage
compliance, or HVAC worst-performer scorecard — returned as download links.
query_deficiencies
Page through equipment and site deficiencies — filter by status, priority, area, site, device, assignee, tag, dates or text — or get just the count.
count_deficiencies_by
Roll deficiencies up by status, priority, area, site, device or assignee, with open, repair-required, critical and overdue counts per group.
get_deficiency
Read one deficiency in full — equipment, history, resolution and assignee — plus the etag used to guard updates.
create_deficiency
Log a new deficiency against a site and, optionally, a device, sensor or lighting load. Safe to retry with an idempotency key.
update_deficiency
Change description, notes, priority, area, due date or tags. Every change is recorded in the deficiency history.
set_deficiency_status
Move a deficiency through open, delayed, repair in progress, resolved and closed. Resolving needs a resolution; reopening needs a reason.
assign_deficiency
Assign a deficiency to an active user on the customer (or NexRev staff) and set a due date — or unassign it.